跳转到主内容

多风扇故障警报、系统在更换PSU模块后发出噪音

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • AFF 和 FAS 系统
  • ONTAP 9
  • 磁盘架

问题描述

  • 两个节点都会在事件日志中频繁报告以下警报:

[Node-01: statd: monitor.shelf.fault:debug]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
[Node-01: statd: monitor.fan.failed:debug]: Multiple fans has failed.
[Node-01: env_mgr: monitor.fan.warning:debug]: multiple fans have failed. Replace it to avoid overheating
[Node-01: env_mgr: callhome.c.fan.fru.fault:debug]: Call home for CHASSIS FAN FRU FAILED: Multiple fans have failed

  • 的输出 storage show fault 显示未检测到某个电源:

::> system node run -node * -command storage show fault

Enclosure Status: unrecoverable
Channel: 0a
Shelf: 0
Shelf Type: DS224-12
Product Serial Number: 952240001855
Module Type: IOM12E

Power Supplies:
Element Status      Status Bytes  Status Descriptions
  1: OK         01,00,00,20   RQSTED ON
 2: NOT INSTALLED    05,00,00,20  

Fans:
Element Status      Status Bytes  Status Descriptions
  1: OK         01,02,EC,26   
  2: OK         01,02,EC,26   
 3: NOT INSTALLED    05,00,00,20  
 4: NOT INSTALLED    05,00,00,20  

Input Power Monitor:
Element Status      Status Bytes  Status Descriptions
  1: OK         01,00,29,07   
 2: NOT INSTALLED    05,00,00,00  

Power Crest Factor:
Element Status      Status Bytes  Status Descriptions
  1: OK         01,00,29,07   
 2: NOT INSTALLED    05,00,00,00

  • 即使在更换PSU后、SP传感器也无法报告读数:

Sensor Name        State      Current   Critical    Warning    Warning   Critical
                     Reading     Low      Low      High     High
-------------------------------------------------------------------------------------------------
SNMP Bad Fan Count            MULTI_FAILED
Chassis is Under Temp             NO
Chassis is Over Temp             NO
PSU2 Bad          invalid       --
PSU1 Bad                  FALSE
PSU2            invalid       --
PSU1                    GOOD
PSU2 ON                    ON
PSU1 ON                    ON
PSU1 INFO                 FRU_AVAIL
PSU1 INFO                 FRU_AVAIL
PSU1 FRU                  GOOD
PSU2 FRU                 MULTIFAULT
Partner Status              A_SIDE_PRESENT
PSU1 Present               PRESENT  
PSU2 Present        not_available    --
PSU2 5V          not_available    -- mV     --      --      --      --     
PSU2 12V          not_available    -- mV     --      --      --      --     
PSU2 5V Curr        not_available    -- mA     --      --      --      --     
PSU2 12V Curr       not_available    -- mA     --      --      --      --     
PSU2 Fan 1         not_available    -- RPM    --      --      --      --     
PSU2 Fan 2         not_available    -- RPM    --      --      --      --     
PSU2 Inlet Temp      not_available    -- C      0 C      5 C     57 C     62 C    
PSU2 Hotspot Temp     not_available    -- C      0 C      5 C     90 C     100 C    
PSU_FAN                  FAIL_2