由于缺少路径、多个磁盘托架出现故障

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

DS460C

问题描述

  • 多个磁盘在不同抽盒的磁盘架中显示出现故障
  • 具有相同IOM的不同抽盒的路径在的输出中显示错误 ::> system node run -node <node name> -command storage show fault -v

Enclosure:
Element Status Status Bytes Status Descriptions
1: OK 01,00,02,00 FAIL

Drawers Control Module:
Element Status Status Bytes Status Descriptions
1 [IOM12B A] : OK 01,00,01,01 REPORT, TYPE BIT0
2 [IOM12B A] : OK 01,00,01,01 REPORT, TYPE BIT0
3 [IOM12B A] : OK 01,00,01,01 REPORT, TYPE BIT0
4 [IOM12B A] : OK 01,00,01,01 REPORT, TYPE BIT0
5 [IOM12B A] : OK 01,00,01,01 REPORT, TYPE BIT0
6 [IOM12B B]   : NONCRITICAL    03,00,11,01  REPORT, PATH FAIL, TYPE BIT0
7 [IOM12B B]   : NONCRITICAL     03,00,11,01   REPORT, PATH FAIL, TYPE BIT0
8 [IOM12B B]   : OK         01,00,01,01   REPORT, TYPE BIT0
9 [IOM12B B]   : NONCRITICAL    03,00,11,01  REPORT, PATH FAIL, TYPE BIT0
10 [IOM12B B]   : NONCRITICAL     03,00,11,01   REPORT, PATH FAIL, TYPE BIT0

  • 重新拔插IOM后、磁盘似乎工作正常、但报告新的IOM错误:
Drawers Control Module:
Element Status            Status Bytes  Status Descriptions
  1 [IOM12B A]   : NONCRITICAL    03,00,11,01  REPORT, PATH FAIL, TYPE BIT0
  2 [IOM12B A]   : NONCRITICAL     03,00,11,01   REPORT, PATH FAIL, TYPE BIT0
  3 [IOM12B A]   : NONCRITICAL     03,00,11,01   REPORT, PATH FAIL, TYPE BIT0
  4 [IOM12B A]   : NONCRITICAL     03,00,11,01   REPORT, PATH FAIL, TYPE BIT0
  5 [IOM12B A]   : NONCRITICAL     03,00,11,01   REPORT, PATH FAIL, TYPE BIT0
  6 [IOM12B B]   : OK         01,00,01,01   REPORT, TYPE BIT0
  7 [IOM12B B]   : OK         01,00,01,01   REPORT, TYPE BIT0
  8 [IOM12B B]   : OK         01,00,01,01   REPORT, TYPE BIT0
  9 [IOM12B B]   : NONCRITICAL    03,00,11,01  REPORT, PATH FAIL, TYPE BIT0
 10 [IOM12B B]   : OK         01,00,01,01   REPORT, TYPE BIT0