跳转到主内容

LUN 在“ LUN 显示”命令输出中不可见

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • ONTAP 9.4P6及更高版本
  • SAN

问题描述

  • LUN在中不可见 lun show,但在 完整路径中可见。
  • LUN在AutoSupport中也不可见。
  • debug smdb table d_vdisk_lun show 正确显示LUN类型、但 vdom dump -metafile vtoc 显示 命名空间标志 不为0:

示例:

::*> debug smdb table d_vdisk_lun show -node NETAPP -dsid 5846 -type-filter all -fields type
node       dsid snapshot qtree lun           type
--------------- ---- -------- ----- ---------------------- ----
NETAPP          5846 ""   ""  test_lun.lun           lun

::*> node run -node * -command vdom dump -metafile vtoc -d 5846 -h
4 entries were acted on.
 
Node: NETAPP
 
VTOC Header Contents
---------------------
Magic Number: 1668248694
Major Version:  3
Minor Version:  2
Volume Flags: 0
Vdisk Count: 1
Sync op ctx:     0
Sync op gsid:    0
 
Namespace Name: test_lun.lun
Base fileid: 97
Record Contents:
    Base generation: 1200408254
    Clone parent fileid: 0
    Clone parent generation: 0
    Clone snapid: 0
   Flags: 2
 
vdom dump vtoc: found 1 records in 1 msecs