跳转到主内容

LED1或LED2传感器达到非临界阈值上限并导致环境停机

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • AFF A400、AFF C400
  • ASA A400、ASA C400、
  • FAS8300、FAS8700
  • AFF A800、AFF C800
  • ASA A800、ASA C800
  • ONTAP 9

问题描述

  • 温度传感器LED1和LED2会在°达到非临界阈值上限(43 C)时触发环境停机、而不是通常触发环境停机的临界阈值上限:

[Node1: env_mgr: monitor.shutdown.chassisOverTemp:EMERGENCY]: Chassis temperature is too hot: Ambient temperature is warning high. System will be shutdown in 2 minutes
[Node1: env_mgr: monitor.chassisTemperature.warm:alert]: Chassis temperature is too warm: LED2 Temp is warning high (43 C).
[Node1: monitor: monitor.globalStatus.critical:EMERGENCY]: Chassis temperature is too high..
[Node1: env_mgr: callhome.chassis.overtemp:EMERGENCY]: Call home for CHASSIS OVER TEMPERATURE SHUTDOWN
[Node1: env_mgr: callhome.chassis.hitemp:error]: Call home for CHASSIS OVER TEMPERATURE

  • HA对中的两个节点均已关闭、从而导致中断。