跳转到主内容

仅从一个节点 AFF A250 看到内部磁盘

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用于

  • AFF A250
  • AFF C250
  • 内部磁盘

问题描述

  • 从 HA 对中的一个节点看不到驱动器。示例

节点 A

slot 0: Virtual NVMe Host Adapter 0n
10 : NETAPP X4013S17337T6NTE NA53 7325.4GB 4160B/sect (xxxxxxxxx)
11 : NETAPP X4013S17337T6NTE NA53 7325.4GB 4160B/sect (xxxxxxxxx)
12 : NETAPP X4013S17337T6NTE NA53 7325.4GB 4160B/sect (xxxxxxxxx)

节点 B:

slot 0: Virtual NVMe Host Adapter 0n
10 : NETAPP X4013S17337T6NTE NA53 7325.4GB 4160B/sect (xxxxxxxxx)
{Disk 00.11 expected here , but missing}
12 : NETAPP X4013S17337T6NTE NA53 7325.4GB 4160B/sect (xxxxxxxxx)

  • 错误消息示例

[Node_name: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk 0n.11 Shelf 0 Bay 11 [NETAPP   X4013S17337T6NTE NA53] S/N [xxxxxxxxx] UID [...] is missing.