跳转到主内容

在AFF A320平台上处理L2监视器重置

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • AFF A320

问题描述

  • 节点意外重新启动
  • 节点在意外关闭后未重新启动

受影响节点上的BMC日志显示以下内容: 

Record 402: Thu May 05 06:20:35.070000 2022 [ASUP.notice]: First notification email | (REBOOT (abnormal)) WARNING | Send failed
Record 403: Thu May 05 06:20:40.640000 2022 [IPMI.notice]: 0076 | 02 | EVT: 6fc302ff | System_Watchdog | Assertion Event, "Power cycle"
Record 404: Thu May 05 06:20:40.640000 2022 [IPMI Event.critical]: L2 watchdog timeout power cycle

  • 如果节点重新启动、则EMS日志文件可能会显示以下错误

Thu May 05 15:33:43 +0800 [netapp: splog_main: mgr.boot.reason_abnormal:EMERGENCY]: System rebooted due to a watchdog reset.
Thu May 05 15:33:43 +0800 [netapp: splog_main: callhome.reboot.watchdog:alert]: Call home for REBOOT (watchdog reset)

  • 如果节点无法重新启动、则  BMC中的system sensors 可能会将 Attn_Sensor1 显示 为 Asserted

Power_Event    | 0x0     | discrete   |       | na     | na     | na     | na
System_FW_Status | 0x0     | discrete   | 0x2f     | na     | na     | na     | na
Wrench_Port_Up   | 0x0     | discrete   | Enabled   | na     | na     | na     | na
Attn_Sensor1    | 0x0     | discrete   | Asserted  | na     | na     | na     | na