问题描述

  • 的故障LED亮起SP-LATEST-RUNTIME

========
FRU LEDs status
======================
<snip>
FRU LED ID 14 = BMC DIMM Slot 2 Attention LED
FRU LED ID 15 = BMC NVMEM 1 Attention LED
FRU LED ID 16 = BMC BOOT DISK Attention LED
<snip>
FRU LED ID 14 is off
FRU LED ID 15 is on 
FRU LED ID 16 is off

  • 错误事件是从SP-LATEST-IPMI 报告的。

 Node        ID  Event Location            Event Description
 ---------------- --- ----------------------------------  ----------------------
      node-01  1 Device in M.2 PCIe slot 1 in Controller A  NVMe device failed

  • EMS 显示Flash Cache脱机。

Mon May 12 19:17:16 +0100 [Node Name: node01: callhome.nvme.exhausted:alert]: Callhome for Flash Cache NVMe Offline.

  • SYSCONFIG -A 显示Flash Cache失败。

slot 1: Flash Cache NVMe
Part Number: 119-00329
Hardware Revision: A0
Firmware Version: NA03
Model Name: X3311A
Capacity: 1024 GB
State: failed