跳转到主内容

由于DomainMisf场 故障、控制器上的LED指示灯出现故障

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • AFF C400
  • AFF A800
  • AFF A700
  • NS224磁盘架

问题描述

  • 控制器上的故障LED亮起
  • 在EMS中接收以下警报
[Node-02: schmd: hm.alert.raised:alert]: Alert Id = DomainMismatchFromNodeToShelf_Alert , Alerting Resource = Switch-02(XXXXXXXXXXX) raised by monitor system-connect
[Node-02: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process schm: DomainMismatchFromNodeToShelf_Alert[Switch-02(XXXXXXXXXXX)].
  • 出现运行状况警报
Cluster::> system health alert show
               Node: Node-02
           Alert ID: DomainMismatchFromNodeToShelf_Alert
           Resource: Switch name: Switch-02(XXXXXXXXXXXX)
           Severity: Major
    Indication Time: Sat Apr 02 16:24:02 2022
           Suppress: false
        Acknowledge: false
     Probable Cause: The storage domain between the nodes Node-01,
                     Node-02 and switch Switch-02 is different
                     from the domain between the switch and shelves 3.1,
                     3.2.
    Possible Effect: This issue will affect conversions to direct-attached
                     storage.
Corrective Actions: Connect the switch Switch-02 to both the node and
                     the shelves with the same storage domain, following
                     the guide applicable to your shelf.