跳转到主内容

false "SwitchFanNotPresent_Alert"反复报告并清除

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用于

  • 集群交换机运行状况监控器(CSHM)
  • 集群网络交换机

问题

  • 尽管集群交换机上未出现任何问题、但仍会收到以下AutoSupport警报。示例

Call home for Health Monitor process cshm: SwitchFanNotPresent_Alert...

  • 警报会在几秒或几分钟内发出并清除。示例

Sun Jan 1 00:00:36 +0100 [node_name: cshmd: hm.alert.raised:alert]: Alert Id = SwitchFanNotPresent_Alert , Alerting Resource = switch_name-1/Fan Module-1 raised by monitor ethernet-switch

Sun Jan 1 00:03:03 +0100 [node_name: cshmd: hm.alert.cleared:notice]: Alert Id = SwitchFanNotPresent_Alert , Alerting Resource = switch_name-1/Fan Module-1 cleared by monitor ethernet-switch

  • 其他传感器也可能正在发出呼叫,例如电源。示例: 

Sun Jan 1 00:05:23 +0100 [node_name: cshmd: hm.alert.raised:alert]: Alert Id = SwitchPowerNotPresent_Alert , Alerting Resource = switch_name-1/PowerSupply-1 raised by monitor ethernet-switch
Sun Jan 1 00:05:23 +0100 [node_name: cshmd: hm.alert.raised:alert]: Alert Id = SwitchPowerNotPresent_Alert , Alerting Resource = switch_name-1/PowerSupply-2 raised by monitor ethernet-switch
Sun Jan 1 00:08:16 +0100 [node_name: cshmd: hm.alert.cleared:notice]: Alert Id = SwitchPowerNotPresent_Alert , Alerting Resource = switch_name-1/PowerSupply-1 cleared by monitor ethernet-switch
Sun Jan 1 00:08:16 +0100 [node_name: cshmd: hm.alert.cleared:notice]: Alert Id = SwitchPowerNotPresent_Alert , Alerting Resource = switch_name-1/PowerSupply-2 cleared by monitor ethernet-switch

  • 管理网络子网限制流量
  • 防火墙应允许从交换机到节点的 HTTPS 和 SNMP 流量。