适用场景

  • AFF A400
  • FAS8300
  • FAS8700

问题描述

  • 系统可能无法  开机自检并进入加载程序提示符。
  • BIOS停留在重置循环中、如下所示:

BIOS Version: 16.3
PEI start.
CPU PEI initialization.
Wait BMC self-test result.
BMC self-test: OK.
UPI initialization.
CPU initialization.
Running full memory initialization.
CPU reset.
BIOS Version: 16.3
PEI start.
CPU PEI initialization.
Wait BMC self-test result.
BMC self-test: OK.
UPI initialization.
CPU initialization.
BIOS Version: 16.3
PEI start.
CPU PEI initialization.
Wait BMC self-test result.
BMC self-test: OK.
UPI initialization.
CPU initialization.
Running full memory initialization.

  • 在此状态下、BMC仍可完全正常运行、并可通过Ctrl-G远程访问或从串行控制台访问