适用场景

  • ONTAP 9
  • AF/FAS系统
  • IOM12E磁盘架模块

问题描述

  • EMS报告以下磁盘架故障:

[Node-02: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
[Node-01: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
[Node-01: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
[Node-02: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT

  • STORAGE-FAULT 输出:

::> system node run -node <node_name> -command storage show fault
Enclosure Status: critical
Channel: 0a
Shelf: 0
Shelf Type: DS224-12
Product Serial Number: XXXXXXXXXXXXXXX
Module Type: IOM12E

Enclosure:
Element Status      Status Bytes  Status Descriptions
  1: OK         01,00,02,00   FAIL
  
Vendor Unique Element 85-IOM12E: (ACP)
Element Status            Status Bytes  Status Descriptions
  1 [IOM12E A]   : CRITICAL      02,18,00,40   NO ACPP, INBACP, FAIL
  2 [IOM12E B]   : CRITICAL      02,18,00,40   NO ACPP, INBACP, FAIL

  • 服务处理器重新启动后、问题描述仍会保留。
  • 在系统上禁用并重新启用ACP没有任何帮助。
  • 重新启动IOM不会解决问题描述问题。