适用场景

AFF/FAS

问题描述

  • 节点关闭、事件日志中显示以下消息:

[Node-01:nvram.battery.power.fault:EMERGENCY]: The NVRAM battery is not receiving power. To prevent data loss, the system will shut down in 5 minutes.
[Node-01:callhome.battery.failure:EMERGENCY]: Call home for BATTERY (power fault) CRITICAL.
[Node-01:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery power fault)

  • 启动时的控制台消息: 

WARNING:  The battery is experiencing a critical failure:
      - Battery power fault
      Without a working battery, the system cannot retain data
      during a power outage, which can result in data loss.
      Power down the system and verify that the battery is
      properly installed.
      To ignore this failure and boot the system in a mode
      where data loss might occur, press 'c' followed by 'Enter'

  • 系统已启动、并提供了足够的时间来为NVRAM电池充电
  • SP/BMC固件已更新为最新可用版本