适用场景

  • FAS8700
  • ONTAP 9.12.1
 

问题描述

EMS报告 monitor.globalStatus.critical 消息、 但很快恢复正常。

示例:

Mon Aug 07 14:00:33  [node01: cfdisk_config: cf.disk.skipped:notice]: The disk 3d.20.9 was skipped because it reported the status disk failed.
Mon Aug 07 14:30:05  [node01: dmgr_thread: raid.disk.missing:info]: Disk 3d.20.9 Shelf 20 Drawer 1 Slot 9 Bay 9 [NETAPP   X375_WVELE04TA07 NA01] S/N [V3GV7X5J] UID [5000CCA0:C42FBD58:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing from the system
Mon Aug 07 14:30:18  [node01: statd: monitor.shelf.warning:error]: Fault reported on disk storage shelf attached to channel 0c. Check fans, power supplies, disks, and temperature sensors.
Mon Aug 07 14:31:00  [node01: monitor: monitor.globalStatus.critical:EMERGENCY]: Disk shelf fault.
Mon Aug 07 14:32:00  [node01: monitor: monitor.globalStatus.ok:notice]: The system's global status is normal.