跳转到主内容

EMS 日志报告 "scsi.cmd.notReadyCondition"

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用于

  • FAS8200
  • FAS9000
  • FAS2750
  • ONTAP 9
  • X377_HLBRE10TA07
  • X318_HLBRE08TA07 - 固件 NA00
  • X318_HARHE08TA07 - 固件 NA01

问题描述

  • 从 EMS 日志中可以确认以下输出。
  • 暂时检测到 scsi.cmd.notReadyCondition 消息,后续重试已确认成功。

示例:

Wed Aug 06 05:03:58 +0900 [node_name: scsi_cmdblk_strthr_admin: scsi.cmd.checkCondition:error]: Disk device 0a.01.7: Check Condition: CDB 0x2f:1f78fc00:0400: Sense Data SCSI:no sense -  (0x0 - 0x0 0x0 0x0)(31).
Wed Aug 06 05:03:58 +0900 [node_name: scsi_cmdblk_strthr_admin: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0a.01.7: Adapter detected hardware error: HA status 0xb: cdb 0x2f:1f78fc00:0400.
Wed Aug 06 05:04:18 +0900 [node_name: scsi_cmdblk_strthr_admin: scsi.cmd.notReadyCondition:notice]: Disk device 0a.01.7: Device returns not yet ready: CDB 0x88:00000001b86540c8:00000008: Sense Data SCSI:not ready - Drive spinning up (0x2 - 0x4 0x1 0x2)(19408).
Wed Aug 06 05:04:19 +0900 [node_name: scsi_cmdblk_strthr_admin: scsi.cmd.retrySuccess:debug]: Disk device 0a.01.7: request successful after retry #0/#11: cdb 0x28:071bfc90:0008 (20428).