跳转到主内容

ONTAP升级后会显示重复的聚合

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • FAS2750
  • 自动化无中断升级(ANDU)
  • 后台磁盘固件更新(BDFU)
  • 通过9.8P21从ONTAP 9.7P15 9.10.1P17升级

问题描述

  • 在ONTAP从9.8P21升级到9.10.1P17期间,磁盘(0b.00.11 )脱机并 标记为缺失。
    • 磁盘固件更新导致磁盘脱机。
    • 聚合 aggr01  已降级并缺少磁盘。

node04 EMS日志:

 [?]  Thu Dec 12 21:17:46 +0900 [node04: cf_giveback: ha.giveback.sysCommit:info]: Subsystem qos_ll_sfo_giveback took 151 msecs to commit giveback of aggregate 'aggr01'.
 [?]  Thu Dec 12 21:17:46 +0900 [node04: config_thread: raid.disk.assign.offline_ref:debug]: aggregate /aggr01/plex0/rg0/0b.00.5 assigned as an offline reference storage for /aggr01/plex0/rg0/0b.00.11.
 [?]  Thu Dec 12 21:17:46 +0900 [node04: config_thread: raid.disk.assign.offline_ref:debug]: aggregate /aggr01/plex0/rg0/0a.01.3 assigned as an offline reference storage for /aggr01/plex0/rg0/0b.00.11.
 [?]  Thu Dec 12 21:17:46 +0900 [node04: config_thread: raid.rg.degraded:notice]: : Raid group /aggr01/plex0/rg0 is degraded
 [?]  Thu Dec 12 21:17:46 +0900 [node04: config_thread: raid.disk.offline:notice]: Marking Disk /aggr01/plex0/rg0/0b.00.11 Shelf 0 Bay 11 [NETAPP   X343_SSKBE1T8A10 NA02] S/N [WXXXXXXN] UID [5000C500:DE81263B:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] offline.
 [?]  Thu Dec 12 21:17:46 +0900 [node04: bg_disk_fw_update_admin: bdfu.selected:info]: Disk 0b.00.11 [NETAPP   X343_SSKBE1T8A10 NA02] S/N [WXXXXXXN] selected for background disk firmware update.
 [?]  Thu Dec 12 21:17:46 +0900 [node04: config_thread: raid.disk.online:notice]: Onlining Disk /aggr01/plex0/rg0/0b.00.11 Shelf 0 Bay 11 [NETAPP   X343_SSKBE1T8A10 NA02] S/N [WXXXXXXN] UID [5000C500:DE81263B:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]

 

  • 交还后,将使用备用磁盘0b.00.23 重建它。

node03 EMS日志:

 [?]  Thu Dec 12 21:17:47 +0900 [node03: config_thread: raid.rg.recons.missing:notice]: RAID group /aggr01/plex0/rg0 is missing 1 disk(s).
 [?]  Thu Dec 12 21:17:47 +0900 [node03: config_thread: raid.rg.recons.info:notice]: Spare disk 0b.00.23 will be used to reconstruct one missing disk in RAID group /aggr01/plex0/rg0.
 [?]  Thu Dec 12 21:17:47 +0900 [node03: config_thread: raid.rg.recons.start:notice]: Disk /aggr01/plex0/rg0/0b.00.23 Shelf 0 Bay 23 [NETAPP   X343_SSKBE1T8A10 NA02] S/N [WXXXXXXG] UID [5000C500:DE8204D7:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]: starting reconstruction, using disk 0b.00.23, disk block 5248.
 [?]  Thu Dec 12 21:17:47 +0900 [node03: config_thread: raid.vol.undestroy.info.missing:info]: params: {'disk_info': 'Disk /aggr01/plex0/rg0/0b.00.23 Shelf 0 Bay 23 [NETAPP   X343_SSKBE1T8A10 NA02] S/N [WXXXXXXG] UID [5000C500:DE8204D7:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]', 'shelf': '0', 'bay': '23', 'vendor': 'NETAPP  ', 'model': 'X343_SSKBE1T8A10', 'firmware_revision': 'NA02', 'serialno': 'WXXXXXXG', 'disk_type': '4', 'disk_rpm': '10000', 'carrier': '', 'site': 'Local'}

  • 更换 另一个故障磁盘后、  node04 故障转移状态已更改为部分恢复。

::> storage failover show
                Takeover
Node       Partner     Possible State Description
-------------- -------------- -------- -------------------------------------
node03   node04   true    Connected to node04
node04    node03   true    Connected to node03, Partial giveback
2 entries were displayed.

  • 在两个HA节点上,都会显示aggr01 ,而在node04 上,仅会显示缺少的磁盘,而其他节点则标记为FAILED

node04 Sysconfig -r:

Aggregate aggr01 (failed, raid_dp, partial, fast zeroed) (block checksums) Plex /aggr01/plex0 (offline, failed, inactive) RAID group /aggr01/plex0/rg0 (partial, block checksums)

  RAID Disk Device      HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)   Phys (MB/blks)
  --------- ------      ------------- ---- ---- ---- ----- --------------   --------------
  dparity  FAILED         N/A             1713523/ -
  parity   FAILED         N/A             1713523/ -
  data    FAILED         N/A             1713523/ -
  data    FAILED         N/A             1713523/ -
  data    FAILED         N/A             1713523/ -
  data    FAILED         N/A             1713523/ -
  data    FAILED         N/A             1713523/ -
  data    0b.00.11     0b   0   11  SA:B   0   SAS 10000 1713523/3509295616 1716957/3516328368 (fast zeroed)
  data    FAILED         N/A             1713523/ -
  data    FAILED         N/A             1713523/ -
  data    FAILED         N/A             1713523/ -
  data    FAILED         N/A             1713523/ -
  data    FAILED         N/A             1713523/ -
  data    FAILED         N/A             1713523/ -
  data    FAILED         N/A             1713523/ -
  data    FAILED         N/A             1713523/ -
  data    FAILED         N/A             1713523/ -
  data    FAILED         N/A             1713523/ -
  data    FAILED         N/A             1713523/ -
  Raid group is missing 18 disks.