跳转到主内容

磁盘架机箱状态报告为备用电源

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • AFF和 FAS系统
  • ONTAP 9
  • DS212C磁盘架

问题描述

  • 磁盘架机箱状态报告 为待机电源

::> system node run -node Node-01 -command storage show fault

Enclosure Status: standby power
Channel: 0a
Shelf: 12
Shelf Type: DS212-12
Product Serial Number: SHXXXXXXXXXXXX
Module Type: IOM12B

Vendor Unique Element 83-IOM12B: (SAS)
Element Status      Status Bytes  Status Descriptions
  1 [IOM12B A]   : CRITICAL      02,88,00,93   MASTER, ADDITIONAL STATUS AVAILABLE, REFERENCE CLOCK FAULT, INTERNAL REGISTER FAULT, RESERVED, RESERVED
  2 [IOM12B B]  : CRITICAL     02,80,00,93   ADDITIONAL STATUS AVAILABLE, REFERENCE CLOCK FAULT, INTERNAL REGISTER FAULT, RESERVED, RESERVED

  •  事件日志中会显示以下警报:

[Node-01: dsa_worker4: ses.status.ModuleError:alert]: DS212-12 (S/N SHXXXXXXXXXXXX) shelf 12 on channel 0a SAS expander error for SAS shelf electronics 1: critical status; Reference Clock Failure. This module is on the rear of the shelf at the top left, on shelf module A.