跳转到主内容

磁盘架固件升级后出现磁盘冗余故障错误

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

FAS8300、 AFF-A700

问题描述

  • 磁盘架固件 升级后、系统位于混合路径中
     

SYSCONFIG-A

System Serial Number: YYYYYYYYYYYY
System Storage Configuration: Multi-Path HA
 
System Serial Number: XXXXXXXXXXXX
System Storage Configuration: Mixed-Path HA

slot 1: SAS Host Adapter 1d (Broadcom SAS3616W rev. 2, SAS, <UP>)
Phy State:[0] Enabled, 12.0 Gb/s
    [1] Enabled, 12.0 Gb/s
    [2] Enabled, 12.0 Gb/s
    [3] Enabled, 12.0 Gb/s
Mini-SAS HD Vendor:     Molex Inc.
Mini-SAS HD Part Number:  112-00437 A0
Mini-SAS HD Type:      Passive Copper (unequalized) 2m end_1
Mini-SAS HD Serial Number: XXXXXXXX
00.33: NETAPP  X377_WVAXE10TA07 NA02 9324.2GB 520B/sect (XXXXXXXX)
00.34: NETAPP  X377_WVAXE10TA07 NA02 9324.2GB 520B/sect (XXXXXXXX)
00.35: NETAPP  X377_WVAXE10TA07 NA02 9324.2GB 520B/sect (XXXXXXXX)
00.48: NETAPP  X377_WVAXE10TA07 NA02 9324.2GB 520B/sect (XXXXXXXX)
00.49: NETAPP  X377_WVAXE10TA07 NA02 9324.2GB 520B/sect (XXXXXXXX)
00.50: NETAPP  X377_WVAXE10TA07 NA02 9324.2GB 520B/sect (XXXXXXXX)
 

EMS-LOG-FILE.GZ

Tue Feb 06 09:28:03 -0500 [nodexxxx: svc_queue_thread: shelf.config.tomixedha:notice]: System has transitioned to a mixture of single, multi-path or quad-path storage configurations.
Tue Feb 06 09:28:03 -0500 [nodexxxx: svc_queue_thread: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED
 
  • 在上述示例中、节点的适配器1d无法检测到磁盘架0的抽盒4
  • 连接到这两个 节点的所有其他适配器都会检测到同一抽盒