跳转到主内容

节点重新启动后、数据端口关闭

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • ONTAP 9
  • AFF系统
  • FAS 系统

问题描述

  • 重新启动节点后、数据端口关闭:
cluster::> system node run -node Node-01 -command sysconfig -a

slot 1: 1G/10G Ethernet Controller CNA EP 8324
(Multiple Dual-port, QLogic CNA 8324(8362) rev. 2)
e1a MAC Address:   02:a0:98:e9:c6:72 (auto-10g_sr-fd-up)
e1b MAC Address:   00:a0:98:e9:bd:f0 (auto-unknown-fd-down)

  • 事件日志中会显示以下消息:

[Node-01: intr: netif.linkDown:info]: Ethernet e1b: Link down, check cable.
[Node-01: vifmgr: vifmgr.portdown:notice]: A link down event was received on node Node-01, port e1b.
[Node-01: vifmgr: vifmgr.reach.unassn:notice]: Network port e1b on node Node-01 is not assigned to any broadcast domain. No broadcast domains appear to be reachable from this port.
[Node-01: vifmgr: vifmgr.reach.skipped:notice]: Network port e1b on node Node-01 was not scanned for reachability because it was administratively or operationally down at the time of the scan.

  • 即使重新拔插SFP和与其连接的缆线后、端口仍保持关闭状态。