跳转到主内容

NS224 机架上的 NSM100 上检测到 DIMM 错误

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • ONTAP 9
  • NS224磁盘架

问题描述

  • 事件日志中报告了有关 NSM 模块上的 DIMM 故障的以下错误:

[Node-01: dsa_worker3: ses.status.dimm.error:error]: NS224NSM100 (S/N SHFGBXXXXXXXX) shelf 0 on channel 0x DIMM failure for Dimm Element 8: not installed or failed. This element is on the DIMM slot 4 in the bottom shelf module (B).

cluster::> storage shelf show -instance
DIMM:
ID Mod Type Size Speed Status Location
--- --- ---- ---- ------- ------------ -------------------------------
1 A DIMM 8GB 2666Mhz normal DIMM slot 1 in the top shelf module (A)
2 A DIMM 8GB 2666Mhz normal DIMM slot 2 in the top shelf module (A)
3 A DIMM 8GB 2666Mhz normal DIMM slot 3 in the top shelf module (A)
4 A DIMM 8GB 2666Mhz normal DIMM slot 4 in the top shelf module (A)
5 B DIMM 8GB 2666Mhz normal DIMM slot 1 in the bottom shelf module (B)
6 B DIMM 8GB 2666Mhz normal DIMM slot 2 in the bottom shelf module (B)
7 B DIMM 8GB 2666Mhz normal DIMM slot 3 in the bottom shelf module (B)
8 B error DIMM slot 4 in the bottom shelf module (B)
  • storage show fault输出,状态报告为未知:

cluster::> system node run -node <node> storage show fault

DIMM:
Element Status            Status Bytes  Status Descriptions
  1 [NSM100 A]   : OK         01,00,00,00
  2 [NSM100 A]   : OK         01,00,00,00
  3 [NSM100 A]   : OK         01,00,00,00
  4 [NSM100 A]   : OK         01,00,00,00
  5 [NSM100 B]   : OK         01,00,00,00
  6 [NSM100 B]   : OK         01,00,00,00
  7 [NSM100 B]   : OK          06,00,00,00
  8 [NSM100 B]   : UNKNOWN       01,00,00,00

  • 您可能会看到磁盘冗余失败警报