跳转到主内容

ONTAP升级后持续发出 vifmgr.cluscheck.ctdpktloss 警报

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • ONTAP 9
  • FAS9000
  • AFF A700
  • 无交换机集群
  • X91440A网络适配器

问题描述

  • 从 9.13.1P13 升级到 9.15.1P11 后,集群报告连续的“vifmgr.cluscheck.ctdpktloss:从集群 LIF 执行 ping 操作时继续丢失数据包”警报。
cluster1::event log> show -event *vifmgr.cluscheck.ctdpktloss*
Time         Node       Severity    Event
------------------- ---------------- ------------- ---------------------------
6/18/2025 09:51:03  cluster1-01    ALERT     vifmgr.cluscheck.ctdpktloss: Continued packet loss when pinging from cluster lif cluster1-01_clus8 (node cluster1-01) to cluster lif cluster1-02_clus8 (node cluster1-02).
6/18/2025 09:50:41  cluster1-01    ALERT     vifmgr.cluscheck.ctdpktloss: Continued packet loss when pinging from cluster lif cluster1-01_clus8 (node cluster1-01) to cluster lif cluster1-02_clus7 (node cluster1-02).
6/18/2025 09:50:19  cluster1-01    ALERT     vifmgr.cluscheck.ctdpktloss: Continued packet loss when pinging from cluster lif cluster1-01_clus8 (node cluster1-01) to cluster lif cluster1-02_clus6 (node cluster1-02).
6/18/2025 09:49:57  cluster1-01    ALERT     vifmgr.cluscheck.ctdpktloss: Continued packet loss when pinging from cluster lif cluster1-01_clus8 (node cluster1-01) to cluster lif cluster1-02_clus5 (node cluster1-02).
6/18/2025 09:49:24  cluster1-01    ALERT     vifmgr.cluscheck.ctdpktloss: Continued packet loss when pinging from cluster lif cluster1-01_clus8 (node cluster1-01) to cluster lif cluster1-02_clus4 (node cluster1-02).
6/18/2025 09:43:39  cluster1-02    ALERT     vifmgr.cluscheck.ctdpktloss: Continued packet loss when pinging from
cluster lif cluster1-02_clus8 (nodecluster1-02) to cluster lif cluster1-01_clus8 (node cluster1-01).
6/18/2025 09:42:54  cluster1-02    ALERT     vifmgr.cluscheck.ctdpktloss: Continued packet loss when pinging from cluster lif cluster1-02_clus7 (node cluster1-02) to cluster lif cluster1-01_clus7 (node cluster1-01).
6/18/2025 09:42:10  cluster1-02    ALERT     vifmgr.cluscheck.ctdpktloss: Continued packet loss when pinging from cluster lif cluster1-02_clus6 (node cluster1-02) to cluster lif cluster1-01_clus6 (node cluster1-01).
6/18/2025 09:41:25  cluster1-02    ALERT     vifmgr.cluscheck.ctdpktloss: Continued packet loss when pinging from cluster lif cluster1-02_clus5 (node cluster1-02) to cluster lif cluster1-01_clus5 (node cluster1-01).
6/18/2025 09:40:39  cluster1-02    ALERT     vifmgr.cluscheck.ctdpktloss: Continued packet loss when pinging from cluster lif cluster1-02_clus4 (node cluster1-02) to cluster lif cluster1-01_clus4 (node cluster1-01).
  • 集群端口已启动,集群 LIF 位于其主端口。
  • 集群端口上未观察到任何错误或丢弃。
  • 此集群最近从使用NetApp CN1610 交换机的集群转换为无交换机集群。
  • 此处使用的集群端口为 e4a、e4b、e4c、e4d、e8a、e8b、e8c、e8d,并且它们配置为分支模式。