跳转到主内容

机箱风扇 FRU 故障且机箱配置无效

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • AFF A150
  • ONTAP 9
  • 集群模式 HA 配置

问题描述

  • 两个节点同时报告“ CHASSIS FAN FRU FAILED: 多个风扇发生故障”:

HA Group Notification from Cluster-01 (CHASSIS FAN FRU FAILED: Multiple fans have failed) ERROR
HA Group Notification from Cluster-02 (CHASSIS FAN FRU FAILED: Multiple fans have failed) ERROR

  • EMS错误显示多个传感器不可用:

[Cluster: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: Multiple fans have failed

  • 以下尝试未能解决问题,无法清除警报。
  1. 已将 BIOS 和 BMC 固件升级到最新版本;
  2. 重启两个节点的 BMC。
  3. 重新安装主板并尝试更换主板。即使使用了新的主板,每个节点在重新安装后仍无法启动,并出现以下错误。

Node A:
+++++++++++++++++++++++++++
Initializing System Memory ...
Loading Device Drivers ...
Waiting for SP ...
IPMI:Read midplane FRU common header:timeout
SP failure. Resetting SP from primary FW. This can take a few minutes
Waiting for SP ...
SP recovered successfully after a reset from primary FW image
Waiting for SP ...
IPMI:Read midplane FRU common header:failed
Configuring Devices ...

CPU = 2 Processor(s) Detected.
  Intel(R) Xeon(R) CPU D-1557 @ 1.50GHz (CPU 0)
  CPUID: 0x00050664. Cores per Processor = 12
  CPU1 (CPU 1)
  CPUID: 0x00000000. Cores per Processor = 0
32768 MB System RAM Installed.
SATA (AHCI) Device: ATP SATAIII mSATA AF120GSTHI-NT5

Boot Loader version 8.1.0 
Copyright (C) 2000-2003 Broadcom Corporation.
Portions Copyright (C) 2002-2023 NetApp, Inc. All Rights Reserved.
BIOS POST Failure(s) detected: Failed to get FRU data. Abort AUTOBOOT

BMC Event log:
Record 120: Tue Jun 03 14:38:13.347240 2025 [ASUP.notice]: First notification email | (INVALID CHASSIS CONFIGURATION (Incompatible Partner PCM)) CRITICAL | Send failed
Record 121: Tue Jun 03 14:39:26.286753 2025 [ASUP.notice]: First notification email | (INVALID CHASSIS CONFIGURATION (Incompatible Partner PCM)) CRITICAL | Send failed

Node B:
+++++++++++++++++++++++++++
Starting program at 0xffffffff80348000
---<<BOOT>>---
NetApp Data ONTAP 9.14.1P1
random: registering fast source Intel Secure Key RNG
***************************************************
 This platform is not supported in this release.   
 The system will now halt  
***************************************************

BIOS Version: 11.21
Portions Copyright (C) 2014-2023 NetApp, Inc. All Rights Reserved.

Initializing System Memory ...
Loading Device Drivers ...
Waiting for SP ...
BIOS Version: 11.21
Portions Copyright (C) 2014-2023 NetApp, Inc. All Rights Reserved.

Initializing System Memory ...
Loading Device Drivers ...
Waiting for SP ...
IPMI:Read midplane FRU common header:timeout
SP failure. Resetting SP from primary FW. This can take a few minutes
Waiting for SP ...
SP recovered successfully after a reset from primary FW image
Waiting for SP ...
IPMI:Read midplane FRU common header:failed

Configuring Devices ...
CPU = 2 Processor(s) Detected.
  Intel(R) Xeon(R) CPU D-1557 @ 1.50GHz (CPU 0)
  CPUID: 0x00050664. Cores per Processor = 12
  CPU1 (CPU 1)
  CPUID: 0x00000000. Cores per Processor = 0
32768 MB System RAM Installed.
SATA (AHCI) Device: ATP SATAIII mSATA AF120GSTHI-NT5

Boot Loader version 8.1.0 
Copyright (C) 2000-2003 Broadcom Corporation.
Portions Copyright (C) 2002-2023 NetApp, Inc. All Rights Reserved.
BIOS POST Failure(s) detected: Failed to get FRU data. Abort AUTOBOOT

BMC Event log:
Record 444: Tue Jun 03 14:45:55.696857 2025 [ASUP.notice]: First notification email | (INVALID CHASSIS CONFIGURATION (Incompatible Partner PCM)) CRITICAL | Send failed
Record 445: Tue Jun 03 14:47:08.277524 2025 [ASUP.notice]: First notification email | (INVALID CHASSIS CONFIGURATION (Incompatible Partner PCM)) CRITICAL | Send failed

 

4.进行了跨控制器测试,发现了底盘故障。