适用场景

DS2246

问题描述

  • 磁盘架报告严重情况
::> run local storage show fault
Enclosure Status: critical
Channel: 0a
Shelf: 1
Shelf Type: DS2246
Product Serial Number: xxxxxxxxx
Module Type: IOM6
  • 从两个控制器频繁生成警报
HA Group Notification (SHELF_FAULT) WARNING
  • 两个IOM模块处于严重状态、但它们会继续正常运行
Vendor Unique Element 83-IOM6: (SAS)
Element Status   Status           Bytes  Status Descriptions
1 [IOM6 A]    : CRITICAL         02,08,00,A4   MASTER, RESERVED, RESERVED, RESERVED
2 [IOM6 B]    : CRITICAL         02,00,00,A4   RESERVED, RESERVED, RESERVED
  • 所有磁盘都可能显示
Disk Elements:
Element Status                  Status Bytes  Status Descriptions
  0 [Bay  0]: NONCRITICAL      03,00,00,10   DEVICE OFF
  1 [Bay  1]: NONCRITICAL       03,01,00,10   DEVICE OFF
  2 [Bay  2]: NONCRITICAL       03,02,00,10   DEVICE OFF
  ...
 23 [Bay 23]: NONCRITICAL       03,17,00,10   DEVICE OFF
  • 磁盘架传感器可能会显示
Temperature Sensors:
Element Status         Status Bytes  Status Descriptions
  1: NONCRITICAL       03,00,14,01  UT WARNING
  2: CRITICAL          02,00,14,03  UT WARNING, UT FAILURE
  • 一次重新拔插一个IOM模块(在重新插入前卸下至少70秒)未解决问题描述问题