跳转到主内容

执行PSU测试时、两个控制器均关闭

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

FAS2650

问题描述

  • 对磁盘架上的单个PSU执行电源测试时、两个控制器均会关闭
  • EMS日志显示、在chassis under temperate environmental shutdown从PSU断电后、控制器因""而关闭

[Node01: monitor: monitor.globalStatus.critical:EMERGENCY]: Power Supply Status Critical: PSU1. Disk shelf fault.
[Node01: env_mgr: monitor.shutdown.chassisUnderTemp:error]: Chassis temperature is too cold: System temperature is critical low. System will be shutdown in 2 minutes
[Node01: env_mgr: callhome.chassis.undertemp:EMERGENCY]: Call home for CHASSIS UNDER TEMPERATURE SHUTDOWN

  • 环境日志显示PSU传感器7在达到严重的温度不足之前会降低
Shelf temperatures by element:
  [1] 30 C (86 F) (ambient)  Normal temperature range
  [2] 33 C (91 F)  Normal temperature range
  [3] 33 C (91 F)  Normal temperature range
  [4] 33 C (91 F)  Normal temperature range
  [5] 33 C (91 F)  Normal temperature range
  [6] 34 C (93 F)  Normal temperature range
 [7] 3 C (37 F) Undertemperature failure!
  [8] 35 C (95 F)  Normal temperature range
  [9] 49 C (120 F)  Normal temperature range
  [10] 42 C (107 F)  Normal temperature range
  [11] 60 C (140 F)  Normal temperature range
  [12] 36 C (96 F)  Normal temperature range
  [13] 43 C (109 F)  Normal temperature range
  [14] 60 C (140 F)  Normal temperature range
  [15] 37 C (98 F)  Normal temperature range