跳转到主内容

AFF-A400上的警示指示灯一直亮起

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • AF-A400
  • FAS8300

问题描述

  • BMC自动升级在使用传感器策略时遇到争用情况。
  • EMS显示:

[env_mgr: monitor.power.unreadable:error]: A power sensor PVDDQ ABC in the controller module is not readable.
[env_mgr: monitor.power.unreadable:error]: A power sensor PVDDQ DEF in the controller module is not readable.
[env_mgr: monitor.power.unreadable:error]: A power sensor PVDDQ GHI in the controller module is not readable.
[env_mgr: monitor.power.unreadable:error]: A power sensor PVDDQ KLM in the controller module is not readable.
[env_mgr: monitor.power.unreadable:error]: A power sensor P1V05 PCH in the controller module is not readable.
[env_mgr: monitor.temp.unreadable:error]: The controller temperature (System Inlet) is not readable.
[env_mgr: monitor.shutdown.chassisOverTemp:EMERGENCY]: Chassis temperature is too hot: Multiple Internal Temp sensors are unreadable. System will be shutdown in 10 minutes
[env_mgr: monitor.temp.unreadable:error]: The controller temperature (System Outlet) is not readable.
[env_mgr: monitor.temp.unreadable:error]: The controller temperature (LED1 Temp) is not readable.
[env_mgr: monitor.temp.unreadable:error]: The controller temperature (MP Temp1) is not readable.
[env_mgr: monitor.temp.unreadable:error]: The controller temperature (MP Temp3) is not readable.
[env_mgr: monitor.shutdown.cancel:notice]: Automatic shutdown sequence canceled.
[env_mgr: monitor.chassisTemperature.ok:notice]: Chassis temperature is ok.
[env_mgr: monitor.chassisPower.ok:notice]: Chassis power is OK.

  • system fru led show all 显示LED_SYSTEM_ATTEN_01 is on

0  LED_SYSTEM_LOCATION_01 is off
1  LED_SYSTEM_ATTEN_01 is on
2  LED_CONTROLLER_ATTEN_01 is off