跳转到主内容

ONTAP 升级后磁盘上的琥珀色 LED

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • FAS2552
  • 磁盘架类型: DS4246
  • 从 7- 模式 Data ONTAP 软件升级到 ONTAP 9

问题描述

  • ONTAP 升级后,多个磁盘的指示灯呈琥珀色
  • storage show fault -v 命令输出显示琥珀色 LED 指示灯为非严重且被 I/O 模块( IOM )绕过的磁盘

Enclosure Status: non-critical
Channel: 0a
Shelf: 0
Shelf Type: DS4246
Product Serial Number: serial_number
Module Type: IOM6E

Disk Elements:
Element Status                  Status Bytes  Status Descriptions
  0 [Bay  0]: OK                01,00,00,00
  1 [Bay  1]: OK                01,01,00,00
  2 [Bay  2]: OK                01,02,00,00
  3 [Bay  3]: NONCRITICAL       03,03,00,00
  4 [Bay  4]: OK                01,04,00,00
  5 [Bay  5]: OK                01,05,00,00
  6 [Bay  6]: OK                01,06,00,00
  7 [Bay  7]: OK                01,07,00,00
  8 [Bay  8]: NONCRITICAL       03,08,10,04   ENCLOSURE BYPASSED B, BYPASSED B
  9 [Bay  9]: OK                01,09,00,00
 10 [Bay 10]: OK                01,0A,00,00
 11 [Bay 11]: OK                01,0B,00,00
 12 [Bay 12]: OK                01,0C,00,00
 13 [Bay 13]: OK                01,0D,00,00
 14 [Bay 14]: NONCRITICAL       03,0E,10,04   ENCLOSURE BYPASSED B, BYPASSED B
 15 [Bay 15]: OK                01,0F,00,00
 16 [Bay 16]: OK                01,10,00,00
 17 [Bay 17]: OK                01,11,00,00
 18 [Bay 18]: NONCRITICAL       03,12,20,08   ENCLOSURE BYPASSED A, BYPASSED A

  • 重新拔插受影响的驱动器不会修复琥珀色 LED