跳转到主内容

控制器上的琥珀色 LED

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用于

FAS/AFF 系统

问题描述

  • 琥珀色指示灯亮起,但未发现可见问题或警报:

Cluster::> System health alert show
This table is currently empty.

  • 检查日志 SP-LATEST-IPMI 我们看到有一个旧故障,在检查日志后,已解决但未清除

======================================
hsamcmd --fault-show-all
======================================
tag  origin  fld                    fault reason                   count  time
---- ------- ----                   -------------                   ------ -----
1   bmc    /chassis-1/controller-a/nvbatt-1     Bat_Design_Cap: Current Sensor 95 UNC       1    Mon Dec 30 09:33:40 2024

  • 正在检查我们可以看到已报告的事件:

Cluster::> system controller service-event show -instance         
            Node: Node-01
Service Event ID: 1
      Location: NV Battery on Controller A
    Description: Bat_Design_Cap: Current Sensor 95 UNC
     Timestamp: Mon Dec 30 09:33:40 2024

 
  • 这篇文章对您有帮助吗?