适用场景

  • FAS8300
  • FAS8700
  • AFF A400
  • BMC固件134或更早版本

问题描述

  • 系统生成以下AutoSupport警报
Call home for BATTERY (wrong charge) WARNING.
HA Group Notification (BATTERY (wrong charge)) ALERT
HA Group Notification (BATTERY (wrong charge)) WARNING
  • EMS事件日志中会显示以下消息

[Node-01: env_mgr: nvmem.battery.wrongCharge:alert]: The NVMEM battery charger is charging the battery even though the battery is not requesting to be charged. To prevent data loss, the system will shut down in 24 hours.
[Node-01: env_mgr: callhome.battery.warning:alert]: Call home for BATTERY (wrong charge) WARNING.
[Node-01: env_mgr: nvmem.battery.normalCharge:notice]: The NVMEM battery charging status is normal.