跳转到主内容

AFF A250/C250 HIC2 Temp0 失败

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • AFF A250
  • AFF C250
  • X1152

问题描述

  • ONTAP升级后或正常运行期间节点报告底盘温度过高
[Node-01:monitor.globalStatus.critical:EMERGENCY]: Chassis temperature is too high..
  • 节点可能会紧急重启waiting for giveback状态并同时报告 NIC 传感器错误。

PANIC: Uncorrectable Machine Check Error at CPU10. SKL_IIO Error: STATUS<0xbb80000000000e0b>(VALID,UC,EN,MISCV,PCC,S,AR,CORR_ERR_STATUS(0),CORR_ERR_CNT(0),MSCOD(0),MCACOD(0xe0b))MISC<0x0000000064000000>(UCR_BUS_LOG(100),UCR_DEVICE_LOG(0),UCR_FUNCTION_LOG(0),UCR_SEGMENT_LOG(0))IIO Machine Check from device(s):RPT(100,0,0):ErrSrcID(CorrSrc(0x6670),UCorrSrc(0x66a0)), PLX PCIE 9797 switch on Controller, Br[9797](102,20,0): Link down, PLX PCIE 9797 switch on Controller, Br[9797](102,21,0): Link down. ,.  in process idle: cpu10 on release 9.13.1P6 (C)

Waiting for giveback...(Press Ctrl-C to abort wait)
Jul 04 10:24:42 [node1:monitor.temp.unreadable:error]: The controller temperature (HIC2 Temp0) is not readable.
Jul 04 10:24:42 [node1:monitor.temp.unreadable:error]: The controller temperature (HIC2 Temp1) is not readable.
Jul 04 10:26:12 [node1:callhome.chassis.hitemp:error]: Call home for CHASSIS OVER TEMPERATURE

  • PLATFORM-SENSORS.XML 显示传感器不可读

工作卡:

HIC1_TEMP0       | 55.000     | degrees C  | ok    | 1.000     | 3.000     | 5.000     | 101.000   | 103.000   | 105.000
HIC1_TEMP1       | 57.000     | degrees C  | ok    | 1.000     | 3.000     | 5.000     | 101.000   | 103.000   | 105.000

 
 
受损卡出现故障、表示模板0:
HIC2_TEMP0       | na         | degrees C  | na    | 1.000     | 3.000     | 5.000     | 101.000   | 103.000   | 105.000
HIC2_TEMP1       | 53.000     | degrees C  | ok    | 1.000     | 3.000     | 5.000     | 101.000   | 103.000   | 105.000
 
受损卡出现故障、表示模板1:
HIC2_TEMP0    | 52.000    | degrees C  | ok    | 1.000     | 3.000     | 5.000     | 101.000   | 103.000   | 105.000
HIC2_TEMP1    | na      | degrees C  | na    | 1.000     | 3.000     | 5.000     | 101.000   | 103.000   | 105.000
  • SP事件日志显示插槽2中NIC的速度降级
617 | 02/13/2024 | 19:42:41 | Temperature #0x10 | Lower Non-recoverable going low
618 | OEM record ee | Device Bus: 117 Dev: 0 Fun: 0 (slot 2) Failed to train at max link speed/width, retraining cycle 0
- Expected GEN1, actual GEN1
- Expected x16, actual x8
  • 中的NIC缺少端口 SYSCONFIG-A

slot 2: Quad 10G/25G Ethernet Controller CX5-Mezz
  e2a MAC Address:    d0:39:ea:52:c8:5f (auto-unknown-fd-down)
  e2b MAC Address:    d0:39:ea:52:c8:60 (auto-unknown-fd-down)
  Device Type:        CX5 PSID(NAP0000000014)
  Firmware Version:   16.26.4012
  Part Number:        111-04587
  Hardware Revision:  B0
  Serial Number:      032249003452

  • 这篇文章对您有帮助吗?