跳转到主内容

AF-C190在"Sysconfig -a"中显示为AF-A150、因为个性化不匹配

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

AFF C190、报告为 AFF A150型号

问题描述

  • 在HA对中、一个AFF C190控制器型号报告为AFF A150。示例

::> system node run -node node_name-01 -command sysconfig -a
   NetApp Release 9.12.1P2: Wed Apr  5 15:57:43 EDT 2023
   System ID: 0123456789 (node_name-01); partner ID: 0234567891 (node_name-02)
   System Serial Number: 123456789123 (node_name-01)
   ...
   slot 0: System Board 1.5 GHz (System Board XXII F1)
            Model Name:            
AFF-A150

  • 配对节点正确:

::> system node run -node node_name-02 -command sysconfig -a
   NetApp Release 9.12.1P2: Wed Apr  5 15:57:43 EDT 2023
   System ID: 0234567891 (node_name-02); partner ID: 0123456789 (node_name-01)
   System Serial Number: 123456789124 (node_name-02)
   ...
   slot 0: System Board 1.5 GHz (System Board XXII F1)
            Model Name:            
AFF-C190

  • AutoSupport警报消息报告:
EMS message example callhome.sfo.personality:ALERT]: Call home for HA GROUP ERROR: PERSONALITY MISMATCH