跳转到主内容

CONTAP-375087:在成功的服务处理器自动固件更新期间出现错误警报 SPAutoUpgradeFailedMajorAlert

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

问题描述

ONTAP 升级后,尽管自动升级已完成,但仍会生成健康警报 SPAutoUpgradeFailedMajorAlert
Cluster::*> system health alert show
        Node: Node-02
      Alert ID: SPAutoUpgradeFailedMajorAlert
      Resource: SP Upgrade
      Severity: Major
   Indication Time: Sat May 03 08:08:55 2025
      Suppress: false
     Acknowledge: false
   Probable Cause: A Service Processor automatic firmware update failure
           was detected, which can result in Service Processor
           not being updated to the latest available compatible
           firmware package.
   Possible Effect: Suboptimal system behavior can result from Service
           Processor not being updated to the latest available
           compatible firmware package.
 Corrective Actions: 1. Use the "system service-processor image show" command to
display the firmware version that SP is currently booted from.
           2. Manually upgrade Service Processor by using the "system
           service-processor image update" command.
           3. Allow sufficient time for the system to update Service
Processor firmware to the specified SP firmware package.
           4. Contact the technical support if the alert persists.

 
Cluster::*> system health subsystem show
Subsystem      Health
----------------- ------------------
SAS-connect     ok
Environment     ok
Memory       ok
Service-Processor degraded