COTP-248951:ONTAP升级后、集群交换机报告SwitchUnachable_Alert (IP地址不可访问)

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

问题描述

  • 升级ONTAP后、一个或多个节点报告无法访问这些集群交换机:

ClusterA::*> system switch ethernet show
Switch            Type         Address      Model
--------------------------- ------------------ ---------------- ---------------
Switch-A1 
               cluster-network   1.2.3.4      OTHER
Serial Number: Unknown
Is Monitored: false
Reason: IP address not reachable
Software Version: Cumulus Linux version 5.4.0 running on Mellanox
Technologies Ltd. MSN2010
Version Source: LLDP
Switch-A2
               cluster-network   1.2.3.5      MSN2100-CB2FC
Serial Number: Unknown
Is Monitored: false
Reason: IP address not reachable
Software Version: Cumulus Linux version 5.4.0 running on Mellanox
Technologies Ltd. MSN2010
Version Source: LLDP
  • 系统运行状况警报show输出中也会显示一条警报:

Node: ClusterA-01
Alert ID: SwitchUnreachable_Alert
Resource: Switch-A1
Severity: Major
Indication Time: Fri May 03 09:39:17 2024
Suppress: false
Acknowledge: false
Probable Cause: The ethernet switch's IP address is not reachable from the local node.
Possible Effect: Monitoring of the switch and log collection will not function.
Corrective Actions: Ensure that the IP address is reachable or specify the correct reachable IP address.
Node: ClusterA-01
Alert ID: SwitchUnreachable_Alert
Resource: Switch-A2
Severity: Major
Indication Time: Fri May 03 09:39:18 2024
Suppress: false
Acknowledge: false
Probable Cause: The ethernet switch's IP address is not reachable from the local node.
Possible Effect: Monitoring of the switch and log collection will not function.
Corrective Actions: Ensure that the IP address is reachable or specify the correct reachable IP address.