问题描述

  • 这些以太网交换机运行状况监视器警报在升级到 9.13.1 后发生:
    hm.alert.raised: Alert Id = SwitchFanNotPresent_Alert, Alerting Resource = ClusterSwitch(FOCXXXX)/Fan Module-4
    hm.alert.raised: Alert Id = SwitchFanNotPresent_Alert, Alerting Resource = ClusterSwitch(FOCXXXX)/Fan Module-3
    hm.alert.raised: Alert Id = SwitchFanNotPresent_Alert, Alerting Resource = ClusterSwitch(FOCXXXX)/Fan Module-2
    hm.alert.raised: Alert Id = SwitchFanNotPresent_Alert, Alerting Resource = ClusterSwitch(FOCXXXX)/Fan Module-1
  • 直接检查交换机状态时,未报告任何错误。
  • 仅在 Cisco Nexus 3132Q-V (NX3132) 交换机上报告了此问题。
  • 可在 Cisco Nexus 交换机上使用 "show environment fan detail" 命令检查风扇运行状况。
  • 示例:
    Switch> enable
    Switch# show environment fan detail
    Fan:
    ---------------------------------------------------------------------------
    Fan Model Hw Direction Status
    ---------------------------------------------------------------------------
    Fan1(sys_fan1) NXA-FAN-30CFM-F 0.0 front-to-back Ok
    Fan2(sys_fan2) NXA-FAN-30CFM-F 0.0 front-to-back Ok
    Fan3(sys_fan3) NXA-FAN-30CFM-F 0.0 front-to-back Ok
    Fan4(sys_fan4) NXA-FAN-30CFM-F 0.0 front-to-back Ok
    Fan_in_PS1 N2200-PAC-400W -- front-to-back Ok
    Fan_in_PS2 N2200-PAC-400W -- front-to-back Ok
    Fan Zone Speed: Zone 1: 0x3.2