跳转到主内容

CFSHELF-1826: ses.status.temperatureError (...) 磁盘架中温度传感器 1 的温度错误

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

问题描述

  • OPS 前面板中的货架注意 LED 亮起。
  • AutoSupport 环境输出,该传感器中报告了"故障" [1])。示例

Channel: 0a
Shelf: 0
SES device path: local access: 0a.00.99
Module type: IOM12; monitoring is active
Shelf status: critical condition
...
Temperature Sensor installed element list: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11; with error: 1
Shelf temperatures by element:
  [1] 128 C (262 F) (ambient) Overtemperature failure!
  [2] 20 C (68 F)  Normal temperature range
  ...
  [11] 31 C (87 F)  Normal temperature range

  • ONTAP 事件消息示例: 

::> event log show -event *shelf* 
Time         Node        Severity    Event
------------------- ---------------- ------------- ---------------------------
1/2/2025 10:35:00   node_name     EMERGENCY    monitor.globalStatus.critical: Disk shelf fault.
1/2/2025 10:34:28   node_name     ALERT      monitor.shelf.fault: Critical fault reported on disk storage shelf attached to channel 0b. Check fans, power supplies, disks, and temperature sensors.
1/2/2025 10:34:19   node_name     ERROR      ses.status.temperatureError: DS224-12 (S/N SHFHU2048000395) shelf 0 on channel 0c temperature error for Temperature sensor 1: critical status; overtemperature failure. Current temperature: 128 C (262 F). This module is on the front of the shelf on the left, on the OPS panel.
1/2/2025 10:33:52   node_name     DEBUG      stackmon.shelf.discovery.complete: One or more shelves have been discovered.
...