跳转到主内容

CSHM无法监控NVIDIA交换机、原因是型号不受支持

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • ONTAP 9
  • 集群交换机运行状况监控器(CSHM)
  • 集群网络交换机 型号NVIDIA MSN2100-CB2FC

问题描述

  • 系统中会显示以下运行状况警报:

::> system health alert show
        Node: CLUSTER-NODE01
      Alert ID: SwitchLinkDiscoveryProtocol_Alert
      Resource: CLUSTER-SW02
      Severity: Minor
   Indication Time: Wed Mar 13 15:15:12 2024
      Suppress: false
     Acknowledge: false
   Probable Cause: The ethernet switch is using an unsupported link
           discovery protocol.
   Possible Effect: The change of the link discovery protocol on the
           switch is not supported. The connected device will not
           appear in link layer discovery commands.
Corrective Actions: Revert the discovery protocol change on the switch.

        Node: CLUSTER-NODE01
      Alert ID: UnsupportedSwitch_Alert
      Resource: CLUSTER-SW02
      Severity: Major
   Indication Time: Wed Mar 13 15:15:12 2024
      Suppress: false
     Acknowledge: false
   Probable Cause: Unsupported Ethernet switch is detected.
   Possible Effect: Communication problems and network connectivity issues
           occur.
 Corrective Actions: Unsupported Ethernet switch "CLUSTER-SW02
           (10:XX:XX:XX:XX:d8)" found. Connect a supported
           Ethernet switch to the network.

  • 报告受影响的集群网络交换机为 Unsupported Model 、并监控其他管理交换机:​​​​​​

CLUSTER::> system switch ethernet show
Switch            Type         Address      Model
--------------------------- ------------------ ---------------- ---------------
CLUSTER-SW02 
               cluster-network   174.XX.X.19    OTHER
   Serial Number: Unknown
    Is Monitored: true
       Reason: Unsupported Model
  Software Version: Cumulus Linux version 4.4.3 running on Mellanox
           Technologies Ltd. MSN2100
   Version Source: LLDP

Mgmt-sw01 
              management-network 172.XX.XX.12    OTHER
   Serial Number: Unknown
    Is Monitored: false
       Reason: Monitoring Disabled by Default
  Software Version: unknown
   Version Source: CDP/ISDP