问题描述

  • CN1610集群交换机丢失。
  • 交换机运行状况降级、 系统运行状况警报显示以下内容:

Node: node-01
Resource: cluster
Severity: Major
Indication Time: Mon Mar 27 14:39:25 2023
Suppress: false
Acknowledge: false
Probable Cause: Redundant configuration is missing for cluster
switches.

Node: node-01
Resource:  Link Aggregate 1
Severity: Major
Indication Time: Mon Mar 27 18:05:47 2023
Suppress: false
Acknowledge: false
Probable Cause: The cable used to connect switch "sw1/ Link
Aggregate 1" to the ISL port might be faulty.

  • 事件日志中会报告以下警报:

[node-01: cshmd: hm.alert.raised:alert]: Alert Id = ClusterSwitchMissing_Alert , Alerting Resource = Sw1 raised by monitor ethernet-switch

[node-01: cshmd: hm.alert.raised:alert]: Alert Id = ClusterIfIslDownWarn_Alert , Alerting Resource = sw2/ Link Aggregate 1 raised by monitor ethernet-switch

  • 在ONTAP的集群交换机运行状况监控器中看不到该交换机
  • 连接到交换机的所有端口均已关闭。
  • 连接到交换机的控制台会显示以下内容:

The system is restarting due to inconsistent state.

  • 重新启动不会解决问题描述问题。