适用于

  • ONTAP 9
  • FAS/AFF 系统
  • 集群交换机

问题描述

  • 来自 AutoSupport:SwitchUnreachable_Alert 在系统中报告
[Node_01: cshmd: hm.alert.raised:alert]: Alert Id = SwitchUnreachable_Alert , Alerting Resource = SW1(FOCXXXXXXXX) raised by monitor ethernet-switch
 
[Node_01: cshmd: hm.alert.raised:alert]: Alert Id = SwitchUnreachable_Alert , Alerting Resource = SW2(FOCXXXXXXXX) raised by monitor ethernet-switch
  • 一个或多个节点与集群交换机通信失败
  • 运行以下命令时也会看到以下情况
    • Clsuter::> system health alert show Node: node1 Alert ID: SwitchUnreachable_Alert Resource: switch1(YYY26390XXX) Severity: Major Indication Time: Mon Mar 10 14:42:11 2025 Suppress: false Acknowledge: false Probable Cause: The ethernet switch's IP address is not reachable fromthe local node. Possible Effect: Monitoring of the switch and log collection will not function. Corrective Actions: Ensure that the IP address is reachable or specify the correct reachable IP address. Node: Node1 Alert ID: UnsupportedSwitch_Alert Resource: switch1(YYY26390XXX) Severity: Major Indication Time: Mon Mar 10 14:42:33 2025 Suppress: false Acknowledge: false Probable Cause: Unsupported Ethernet switch is detected. Possible Effect: Communication problems and network connectivity issues occur. Corrective Actions: Unsupported Ethernet switch "undcdsa-nsdb01(FDO26390U4P)" found. Connectsupported Ethernet switch to the network.
  • 集群交换机未被集群交换机健康监视器 (CSHM) 监控:
    • ClusterA::> system switch ethernet show
      Switch            Type         Address      Model
      --------------------------- ------------------ ---------------- ---------------
      switch_A_1(xxxxxxxxxxx)    cluster-network   10.1.1.X         NX3132V
         Serial Number: xxxxxxxxxxx
          Is Monitored: false 
            Reason: IP address not reachable
        Software Version: Cisco Nexus Operating System (NX-OS) Software, Version 7.0(3)I4(1)
         Version Source: CDP

  • 这会导致交换机运行状况降级:

::> system health subsystem show
Subsystem         Health
----------------- ------------------      
SAS-connect       ok
Environment       ok
Memory            ok
Service-Processor ok
Switch-Health     degraded
CIFS-NDO          ok
Motherboard       ok