跳转到主内容

Cisco 9336交换机报告温度传感器过高

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • 从NetApp购买的Cisco Nexus 9336交换机
  • NXOS 10.1 ( 1 )
  • NXOS 10.1 ( 2 )

问题描述

  • ONTAP在中报告高温警报 system health alert show:

Sensor "module-1 BACK" on switch "SW-A1(XXXXXXXXXX)" is reporting a temperature of 4294967168 C, which is above the critical threshold

  • show environment中,将显示以下内容
Temperature:
--------------------------------------------------------------------
Module   Sensor        MajorThresh   MinorThres   CurTemp     Status
(Celsius)     (Celsius)    (Celsius)
--------------------------------------------------------------------
1        FRONT           80              70          28         Ok
1       BACK            70              42          n/a        Failure
1        CPU             90              80          36         Ok
1        Heavenly        110             90          45         Ok
  • 可能存在运行状况警报 SwitchTemperatureCritical_Alert

[Node-1: cshmd: hm.alert.raised:alert]: Alert Id = SwitchTemperatureCritical_Alert , Alerting Resource = XXXXXXXXXXXX(XXXXXXXXXXXX)/module-1 BACK raised by monitor ethernet-switch