问题描述

  •   当  超过交换机的传感器温度阈值时、将发送SwitchTemperatureWarn_Alert警报。

[node-1: mgwd: callhome.hm.alert.minor:error]: Call home for Health Monitor process cshm: SwitchTemperatureWarn_Alert[cluster-sw01(FDXXXXXXXZD)/module-1 BACK].

  • 交换机日志指示当前温度超过阈值。 

cluster-sw01# show environment

Temperature:
--------------------------------------------------------------------
Module   Sensor     MajorThresh  MinorThres CurTemp   Status
            (Celsius)    (Celsius)   (Celsius)
--------------------------------------------------------------------
1     FRONT       80        70      44      Ok
1     BACK       70        42     44    MinorAlarm
1     CPU        90        80      58      Ok
1     Heavenly     110        90      66      Ok

  • SwitchTemperatureCritical_Alert AutoSupport警报可能也会与此问题描述一起显示。
  • 如果交换机温度 持续超过温度阈值、则交换机可能会关闭