跳转到主内容

连接到Brocade交换机的HPE互连端口已关闭

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • Brocade互联阵列
  • HPE互连

问题描述

  • 连接到Brocade交换机的HPE互连端口/上行链路已关闭
  • 在服务器和交换机之间使用4根SFP分支缆线连接QSFP
  • 在Brocade交换机上,所有4个互连端口都处于 Disabled 下的状态 switchshow
 /fabos/bin/switchshow: switchName: SWXXXX switchType: 118.1 switchState: Online Index Port Address Media Speed State Proto ================================================== 8 8 010800 id N16 No_Sync FC Disabled (Port Throttled) 9 9 010900 id N16 No_Sync FC Disabled (Port Throttled) 10 10 010a00 id N16 No_Sync FC Disabled (Port Throttled) 11 11 010b00 id N16 No_Sync FC Disabled (Port Throttled)
  • Porterrshow 报告 Loss of signal 互连端口上的错误。
 /fabos/cliexec/porterrshow: frames enc crc crc too too bad enc disc link loss loss frjt fbsy c3timeout pcs uncor 8: 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 9: 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 10: 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 11: 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0