跳转到主内容

Brocade 交换机状态显示有故障,所有端口均已脱机

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用于

  • Brocade (G630)
  • Brocade (G620)
  • Brocade (G610)

问题描述

  • 所有交换机端口进入离线/故障状态,交换机状态显示为故障。
  • 所有端口进入禁用模式
  • Errdump显示如下:

2020/01/28-01:23:14, [EM-1134], 35579, FFDC | CHASSIS, ERROR, SEMLFCSW02_CH, Switch set to faulty, rc=20015.

  • RASPOST logs 显示以下内容:

2020/01/28-01:23:14:334606, [C4-5813], 45282/0, CHASSIS, INFO, SEMLFxx2_CH, S0,C0: Chip fault code = 53 disables condor4 chip, OID:0x43010080, c4_intr.c, line: 4357, comp:insmod, ltime:2020/01/28-01:23:14:334041

2020/01/28-01:23:14:334628, [BL-5215], 45283/0, CHASSIS, WARNING, SEMLFxx2_CH, ASIC error/fault message received for chip = 0 ,reason = 53, OID:0x43010080, pulsar_chip.c, line: 958, comp:emd0, ltime:2020/01/28-01:23:14:334117

2020/01/28-01:23:14:336331, [BL-5263], 45284/0, CHASSIS, CRITICAL, SEMLFxx2_CH, Faulting switch, OID:0x43000000,    pulsar_blade.c, line: 2556, comp:emd0, ltime:2020/01/28-01:23:14:334745Br

  • 交换机时钟中的端口出现大量 pcs uncor err,请尝试禁用该端口,因为它在短时间内报告了大量错误

porterrshow     :
      frames     enc    crc    crc    too    too    bad    enc   disc   link   loss   loss   frjt   fbsy    c3timeout   pcs   uncor
     tx     rx    in   err   g_eof   shrt   long   eof    out   c3    fail   sync   sig            tx    rx    err   err
 11:  426.2k   2.8m   0    166    149     0     0    17     0     0     3.9k   3.9k   3.9k   0     0     0     0    256.0k  227.3k