跳转到主内容

Brocade G7在错误转储中报告故障风扇警报

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • Brocade G7交换机
  • FOS v9.0.1b

问题描述

  • Brocade 交换机报告 风扇故障警报,中标识了相同的映射警报 errdump

2024/06/26-07:35:09, [MAPS-1021], 304, FID 128, WARNING, SSW-02, RuleName=defCHASSISBAD_FAN_CRIT, Condition=CHASSIS(BAD_FAN>=2), Obj:Chassis [ BAD_FAN,2] has contributed to switch status CRITICAL.
2024/06/26-07:34:13, [MAPS-1021], 6, FID 128, WARNING, SSW-01, RuleName=defCHASSISBAD_PWR_CRIT, Condition=CHASSIS(BAD_PWR>=1), Obj:Chassis [ BAD_PWR,1] has contributed to switch status CRITICAL.

  • fanshow 指示日志中的最佳状态。

/fabos/cliexec/psshow -v:

Power Supply #1 is OK
Power Supply #2 is OK

/fabos/cliexec/fanshow:
Fan 1 is Ok, speed is 13605 RPM
Fan 2 is Ok, speed is 13333 RPM