跳转到主内容

Brocade X7 交换机上的备用 CP 进入故障状态

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • Brocade X7交换机
  • FOS v9.2.1a

问题描述

  • Brocade X7 交换机上的备用 CP 已重启。
  • 备用 CP 进入故障状态,并返回到无效状态。

2025/04/28-02:03:56 (IST), [HAMK-1004], 2352808, SLOT 1 | CHASSIS, INFO, sw13, Resetting standby CP (double reset may occur).
2025/04/28-02:03:56 (IST), [FSSM-1003], 2352809, SLOT 1 | CHASSIS, WARNING, sw13, HA State out of sync.
2025/04/28-02:03:56 (IST), [EM-1033], 2352810, SLOT 1 | CHASSIS, ERROR, sw13, CP in Slot 2 set to faulty because CP ERROR asserted.
2025/04/28-02:03:59 (IST), [EM-1047], 2352811, SLOT 1 | CHASSIS, INFO, sw13, CP in slot 2 not faulty, CP ERROR deasserted.
2025/04/28-02:04:22 (IST), [MAPS-1021], 2352812, SLOT 1 | FID 128, WARNING, sw1, RuleName=defCHASSISHA_SYNC_0, Condition=CHASSIS(HA_SYNC/NONE==0), Obj:Chassis [HA_SYNC,0] has contributed to switch status MARGINAL.
2025/04/28-02:04:22 (IST), [MAPS-1020], 2352813, SLOT 1 | FID 128, WARNING, sw1, Switch wide status has changed from HEALTHY to MARGINAL.

  • 备用包上的二级分区显示为 Vpackage。

firmwareshow -v:
Slot Name     Appl    Primary/Secondary Versions         Status
--------------------------------------------------------------------------
  1  CP0     FOS    v9.2.1a                  ACTIVE
             v9.2.1a                  
  2  CP1     FOS    v9.2.1a                  STANDBY *
             vpackage