跳转到主内容

Brocade开关显示电源有故障

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

Brocade 交换机

问题描述

  • 交换机PSU上显示琥珀色指示灯或没有链路指示灯
  • 请检查chassisshow
  • sensorshow 将PSU2报告为“FABHE故障”,将风扇2报告为“未知”。 

sensorshow     :
sensor  1: (Temperature) is Ok, value is 39 C
sensor  2: (Fan 1 ) is Ok,speed is 6617 RPM
sensor  3: (Fan 2 ) is Unknown
sensor  4: (Power Supply) is Ok
sensor  5: (Power Supply) is Faulty

  • psshow 报告电源2出现故障

psshow     :

Power Supply #1 is OK
Power Supply #2 is faulty

  • fanshow 将风扇 2报告为未知

fanshow     :
Fan 1 is Ok, speed is 6617 RPM
Fan 2 is Unknown

  • 根据errdump ,可以看到PS1、PS2 和Fan2都出现故障:

2023/06/21-14:13:39, [EM-1034], 88278, CHASSIS, ERROR, Brocade, PS 2 set to faulty, rc=2000e.
2023/06/21-14:13:41, [FW-1010], 88279, FID 128, WARNING, Brocade, Env Power Supply 2, is below low boundary(High=0, Low=1). Current value is 0 (1 OK/0 FAULTY).
2023/06/21-14:13:41, [FW-1424], 88280, FID 128, WARNING, Brocade, Switch status changed from HEALTHY to MARGINAL.
2023/06/21-14:13:41, [FW-1427], 88281, FID 128, WARNING, Brocade, Switch status change contributing factor Power supply: 1 bad.

2023/06/21-14:13:56, [EM-1034], 88293, CHASSIS, ERROR, Brocade, PS 1 set to faulty, rc=2000e.
2023/06/21-14:14:00, [FW-1010], 88294, FID 128, WARNING, Brocade, Env Power Supply 1, is below low boundary(High=0, Low=1). Current value is 0 (1 OK/0 FAULTY).
2023/06/21-14:14:00, [FW-1424], 88295, FID 128, WARNING, Brocade, Switch status changed from HEALTHY to MARGINAL.
2023/06/21-14:14:00, [FW-1427], 88296, FID 128, WARNING, Brocade, Switch status change contributing factor Power supply: 1 bad.
2023/06/21-14:14:00, [EM-1037], 88298, CHASSIS, INFO, Brocade, PS 1 is no longer faulted.

2023/06/21-14:23:40, [HIL-1610], 88315, CHASSIS, WARNING, Brocade, Fan/PS unit 2 not supplying power, fan speeds may not be available. Please ensure that the unit has power and the switch is on.
2023/06/21-14:23:44, [FW-1431], 88316, FID 2, WARNING, Brocade, Switch status change contributing factor Fan: 1 bad.
2023/06/21-14:23:46, [FW-1431], 88317, FID 128, WARNING, Brocade, Switch status change contributing factor Fan: 1 bad

 

  • 在更换交换机PSU之前、请按照以下步骤进一步排除站点上的任何潜在电源问题、例如电源插座、电缆等:
  1. 检查电源线是否连接正确。
  2. 尝试换用已知良好的电源线。
  3. 重新拔插交换机的电源线和PSU。
  4. 确保外部电源正常运行。

 

注:对于Brocade 6510交换机、风扇集成在电源设备中

发生原因


电源故障