跳转到主内容

由于文件系统问题描述、出现"sensorReadingFaed"和"ensorbleDeded"警报

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • NetApp HCI 存储节点
  • NetApp SolidFire存储节点
  • 在解析此 知识库文章时、重新启动节点时检测到启动介质出现故障

问题描述

  • NetApp SolidFire Active IQ和Element集群Web图形用户界面会显示以下警报:
    • sensorReadingFailed IPMI diagnostics are currently unresponsive. Please contact support if this problem persists.
    • ensembleDegraded Ensemble degraded: 1/5 database servers not connectable: {3:x.x.x.x}
  • 存储节点的远程控制台上显示ext4-fs错误
    • [3367598.061077] EXT4-fs error (device sda2): ext4_journal_check_start:61:Detected aborted journal
    • [3367598.061078] EXT4-fs error (sda2): Remounting filesystem read-only xxxxxxxx
    • [3367598.125694] EXT4-fs error (sda3): in ext4_writepages:2878: IO failure
  • 事件日志显示:

networkEvent Failed to install SSL certificate  3  { "message": "Failed to remove path=[/sf/etc/ssl/active.crt] errorCode=system:30 errorCode.message()=Read-only file system", "name": "xCheckFailure" }
platformHardwareEvent Updating BMC cold reset date 6 3  { "bmcResetDurationMinutes": 0, "bmcResetDate": "2021-05-11T23:16:41" }
unexpectedException Unexpected Exception - xCreateRepositorySourceFileFailed Failed to open and truncate /sf/apt/sources.list.new.tmp callback=[ {4:RepositorySources::packageManagerCallbackTag}] wtype=[SessionConnected] - Contact SolidFire Support. 6 3  ""

  • 可以正常访问节点的BMC网页、并可访问1G/10G网络
  • 按照解决方案of KB重新启动节点时,在启动期间检测到以下错误:

Version 2.17.1249. Copyright (C) 2017 American Megatrends, Inc.

NetApp H500S BIOS Date:07/10/2017 Rev:NA2.1
CPU : Intel(R) Xenom(R) CPU E5-2620 v4 @ 2.10GHz
 Speed : 2.10 GHz
The IMC is operating with DDR4 2133 MHz

Port 0 : Micron_5100_XXXXXXXXXX
S.M.A.R.T Status Bad, Backup and Replace.
Press F1 to Resume...