跳转到主内容

H410S上的SensorReadingFaif警报

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • NetApp Element软件
  • NetApp H410S (H300S、H500S、H700S)

问题描述

SolidFire ActiveIQ中可能会显示以下错误:

  • Error checking sensor for Inlet Temp (10193x)
  • Error checking sensor for FanX RPM (10193x)

同时, 从管理节点(mNode)运行ipmitool时,各种Temp传感器的输出将显示 Fail 状态(而不是预期的 OK): 

  •  sudo ipmitool -I lanplus -H <node-BMC-IP-address> -U <BMC-username> -P <BMC-password> sdr

sfadmin@NODE /usr/bin $ sudo ./smc-ipmicfg -sdr
Status | (#)Sensor         |    Reading | Low Limit | High Limit |
------ | ---------         |    ------- | --------- | ---------- |
 Fail | (4) CPU1 Temp       |      N/A |     N/A |   98C/208F |
 Fail | (71) CPU2 Temp       |      N/A |     N/A |   98C/208F |
 Fail | (138) PCH Temp       |      N/A |   5C/41F |   95C/203F |
 Fail | (205) System Temp     |      N/A |   -5C/23F |   85C/185F |
  ---omitted---