跳转到主内容

在iSCSI主机上检测到主机端连接冗余丢失

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • NetApp E 系列
  • iSCSI主机

问题描述

  •  报告重大事件日志检测到主机端连接冗余丢失:
示例:
日期/时间:2023-06-17 01:32:45
Sequence number: 2470
Event type: 9102
Event category: Error
Priority: Critical
Event needs attention: true
Event send alert: true
Event visibility: true
Description: Loss of host-side connection redundancy detected
Event specific codes: 0/0/0
Component type: Host
Component location: Host XXXX
Logged by: Controller in bay A
  • Host Redundancy Lost 正在报告Recovery Guru条目:
示例:
Failure Entry 1: ALB_HOST_REDUNDANCY_LOST-Recovery Failure Type Code: 475
Storage array: E2860
Affected host: XXXX
Affected controller: Controller in bay B
  • 此外、可能还会报告卷不在首选路径上的Recovery Guru条目:

Failure Entry 1: NON_PREFERRED_PATH-Recovery Failure Type Code: 10"

  • ISCSI-SESSION-CONNECTIONS Support-Data日志中只有一个控制器具有iSCSI连接:

==iSCSI Session Summary==
Initiator iSCSI name:  iqn.1991-05.com.microsoft:dps01p  
  Sessions/Connections to Controller A:
    10.0.1.29 -> 10.0.1.99  
  Sessions/Connections to Controller B:
   <Empty>