跳转到主内容

在 E 系列 SANtricity 操作系统升级期间, FlexArray ONTAP 多磁盘故障崩溃

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • NetApp FlexArray 解决方案。
    • NetApp ONTAP
    • NetApp E 系列
  • SANtricity OS 11.50.2至11.70.2

问题描述

ONTAP 节点在E系列SANtricity操作系统升级期间遇到多磁盘故障崩溃:

Sun June 22 08:00:54 +0100 [ONTAP_Node_Name: config_thread: cf.multidisk.fatalProblem:info]: Node encountered a multidisk error or other fatal error while waiting to be taken over. aggr AGGREGATE_NAME: raid xxxxx, fatal disk error in RAID group with no parity disk..  Raid type - raid0 Group name plex0/rg0 state NORMAL. 1 disk failed in the group. Disk XXXXXXX:1-XX.XXXLXX Shelf - Bay - [NETAPP   INF-01-00     0870] S/N [6D039EA0000XXXXX000001XXXXXXXXXX] UID [6D039EA0:000XXXXX:00000XXX:XXXXXXXX:00000000:00000000:00000000:00000000:00000000:00000000] error: fatal disk error..