跳转到主内容

E系列控制器冗余丢失- AutoSupport消息

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

NetApp E 系列

事件摘要

SANtricity在恢复专家中报告Controller redundancy lost 事件

验证

  • MAJOR-EVENT-LOG 显示Controller redundancy lostEvent type: 2829

Date/Time: <DATE/TIME>
Sequence number: 557252
Event type: 2829
Event category: Internal
Priority: Critical
Event needs attention: true
Event send alert: true
Event visibility: true
Description: Controller redundancy lost
Event specific codes: 0/0/0
Component type: Controller
Component location: Shelf 99, Bay B
Logged by: Controller in bay B

  • Recoveru Guru 显示备用控制器处于Failed 状态:

Failure Entry XX: OFFLINE_CTL-Recovery Failure Type Code: 28

Storage array: <ARRAY>
Component reporting problem: Controller in bay A
Status: Failed
Location: Controller/Drive shelf 99, Controller in bay A
Replacement part number: E5700A-64GB
Board ID: 5700
Submodel ID: 360
Serial number: <SERIAL NO>
Component requiring service: Controller in bay A
Service action (removal) allowed: Yes
Service action LED on component: No

解决方法

  1. 将备用控制器重新联机。
  2. 如果控制器未保持联机状态、请联系 NetApp技术支持 并参考本文以获得进一步帮助。解决方案可能需要更换部件。
    • 联系NetApp技术支持时,请在E系列控制器的背面显示屏上提供7段代码。这将有助于对控制器问题描述进行故障排除。

追加信息

在此处添加文本。